Description
Control Console CC 5000
For standard applications. Detection – control – extinguishment
Controle console for the evaluation of the signals of spark detectors, for automatic activation of extinguishing and alarm devices. Use of a TOUCH display possible. Types: CC 5001, CC 5002, CC 5004, CC 5016, CC 5036 (Version with TOUCH display possible)
Specifications
- Number of detector lines: max. 36
- Convertible to the potentially explosive area: Yes
- System extendable: No (CC 5001, CC 5002, CC 5004), Yes (CC 5016, CC 5036)
- Housing: Wall mounted housing 1, Wall mounted housing 2, Cabinet 3
- Power drawn max.: approx. 90 VA (CC 5001, CC 5002, CC 5004), approx. 380 VA (CC 5016), approx. 760 VA (CC 5036)
- Power failure bridging time with full capacity: 4 h
- Operating voltage: 95 – 265 V at 47 – 63 Hz
- Protection: 5 AT
- Protection class: IP 55
- Ambient temperature, operation: +5 °C – +40 °C
- Requirements for the installation site: Dry, vibration-free
Control Console CC 7000
Individually programmable for complex control solutions
Controle console for the evaluation of signals of spark detectors, for automatic activation of extinguishing and alarm devices. Use of a TOUCH display possible.
Networking of Control Consoles BS7 NET
Factory-wide visualization and synchronization of control consoles. The networking of control consoles BS7 NET is a real-time bus system and interlinks up to 25 control consoles. The BS7 NET server links BS7 NET with the company network.
Specifications
- Suitable spark detection control consoles: type series CC 7000 (all models), type series CC 5000 (version with master module)
- Master-Module: Master Module BS7 Net
- Method of operation: Standard and BS7 Touch
- Number of networkable control consoles: max. 25
- Number of zones: max. 1000
- Data cable length between two points: up to 100 m copper cable, up to 2 km fibre optic cable, type MultiMode, up to 15 km Fibre optic cable type SingleMode
- Network length total: maximum 30 km
- Bus type: ring line with bus protocol BS7 Net
- Control console numbers: 1 to 25
- Connection sockets BS7 Net: IP 67 (only wall housing)
Fire alarm centers FC 7000
The GreCon fire alarm equipment serves for premises and machine monitoring in an industrial environment.
Specifications
- Types: FC 7008, FC 7020
- Designation: 1 (FC 7008), 2 (FC 7020)
- Number of detector lines: max. 8 (FC 7008), max. 20 (FC 7020)
- Convertable to the potentially explosive area: Yes
- System is extendable: Yes (with max. 2 expansion units)
- Ambient temperature: -5 °C to max. +40 °C
- Power input: 230 VA project-specific
- Standby power supply: 24 V
- Supply voltage: 230 V +10% / -15%
- Protection: 10 A
- Protection type: IP 54
- Installation site: vibration-free, dry